DEHNguard® S ... VA

Pluggable single-pole varistor-based arrester

For protecting low-voltage consumer's installations against surges. For installation in conformity with the lightning protection zone concept at the boundaries from 0B– 1 and higher.
  • Multi-purpose surge arrester consisting of a base part and a plug-in protection module
  • Leakage-current-free series connection of a varistor and a spark gap in the pluggable protection module
  • High reliability due to "Thermo Dynamic Control" SPD monitoring device
  • Energy coordination with other arresters of the Red/Line product family
  • Easy replacement of protection modules without tools due to module locking system with module release button
  • Narrow (modular) design according to DIN 43880
  • Multifunctional terminal for connecting conductors and busbars

Version

DEHNguard S ... VA: Modular single-pole surge arrester with a varistor connected in series with a spark gap in the pluggable protection module
DEHNguard S ... VA FM: Modular single-pole surge arrester with a varistor connected in series with a spark gap in the pluggable protection module; with remote signalling contact for monitoring device (floating changeover contact)

Details

The single-pole DEHNguard S ... VA surge arresters are an ideal supplement to the proven DEHNguard product families. The special series connection of a spark gap and a varistor in the protection module opens up new fields of application. It is advisable to use DEHNguard S ... VA devices to protect, for example, systems with permanent insulation monitoring and the traction power lines in railway systems where complete absence of leakage currents is required. DEHNguard S ... VA surge arresters are also suited for protecting power line communication systems.

Multifunctional terminals allow almost unlimited flexibility of connection to one another, but also to other DIN rail mounted devices on the distribution board. However, it is not only flexibility that characterises the DEHNguard S ... VA family. Its distinctive performance parameters set standards worldwide:
A high discharge capacity, complete absence of leakage currents, a low voltage protection level and the dual "Thermo Dynamic Control" monitoring and disconnection device describe the high degree of reliability.

The DEHN-specific "Thermo Dynamic Control" disconnector ensures that the arresters enter a safe and isolated state, even in case of extreme overload. For this purpose, the surface temperature of the heavy-duty varistor and the intensity of the discharge current are used for evaluation. In addition to the standard visual indication with red and green indicator flags, the DEHNguard S VA ... FM devices feature a three-pole remote signalling terminal. With its floating changeover contact, the remote signal can be used as break or make contact according to the particular protection concept.

Models

DEHNguard S VA

DEHNguard S VA FM

DEHNguard S VA

Basic circuit diagram DG S ... VADimension drawing DG S ... VA

Modular single-pole surge arrester with a varistor connected in series with a spark gap in the pluggable protection module.


Specifications

Type
Part No.
SPD according to EN 61643-11 / IEC 61643-11
Energy coordination with terminal equipment (≤ 10 m)
Nominal voltage (a.c.) (UN)
Max. continuous operating voltage (a.c.) (UC)
Max. continuous operating voltage (d.c.) (UC)
Nominal discharge current (8/20 µs) (In)
Max. discharge current (8/20 µs) (Imax)
Voltage protection level (UP)
Response time (tA)
Max. mains-side overcurrent protection
Short-circuit withstand capability for max. mains-side overcurrent protection (ISCCR)
Temporary overvoltage (TOV) (UT) – Characteristic
Operating temperature range (TU)
Operating state / fault indication
Number of ports
Cross-sectional area (min.)
Cross-sectional area (max.)
For mounting on
Enclosure material
Place of installation
Degree of protection
Capacity
Weight
GTIN
PU
Part No.
  • DG S 75 VA
  • 952 080
  • type 2 / class II
  • type 2 + type 3
  • 60 V (50 / 60 Hz)
  • 75 V (50 / 60 Hz)
  • 100 V
  • 10 kA
  • 20 kA
  • ≤ 1.1 kV
  • ≤ 100 ns
  • 100 A gG
  • 25 kArms
  • 115 V / 120 min. – withstand
  • -40 °C ... +80 °C
  • green / red
  • 1
  • 1.5 mm2 solid / flexible
  • 35 mm2 stranded / 25 mm2 flexible
  • 35 mm DIN rails acc. to EN 60715
  • thermoplastic, red, UL 94 V-0
  • indoor installation
  • IP 20
  • 1 module(s), DIN 43880
  • 107 g
  • 4013364127296
  • 1 pc(s)
  • 952 080
  • Specifications (PDF)
  • More
  • DG S 275 VA
  • 952 082
  • type 2 / class II
  • type 2 + type 3
  • 230 V (50 / 60 Hz)
  • 275 V (50 / 60 Hz)
  • 350 V
  • 10 kA
  • 20 kA
  • ≤ 1.5 kV
  • ≤ 100 ns
  • 100 A gG
  • 25 kArms
  • 440 V / 120 min. – withstand
  • -40 °C ... +80 °C
  • green / red
  • 1
  • 1.5 mm2 solid / flexible
  • 35 mm2 stranded / 25 mm2 flexible
  • 35 mm DIN rails acc. to EN 60715
  • thermoplastic, red, UL 94 V-0
  • indoor installation
  • IP 20
  • 1 module(s), DIN 43880
  • 113 g
  • 4013364127319
  • 1 pc(s)
  • 952 082
  • Specifications (PDF)
  • More
  • DG S 385 VA
  • 952 084
  • type 2 / class II
  • type 2 + type 3
  • 230 V (50 / 60 Hz)
  • 385 V (50 / 60 Hz)
  • 500 V
  • 10 kA
  • 20 kA
  • ≤ 1.75 kV
  • ≤ 100 ns
  • 100 A gG
  • 25 kArms
  • 440 V / 120 min. – withstand
  • -40 °C ... +80 °C
  • green / red
  • 1
  • 1.5 mm2 stranded / flexible
  • 35 mm2 stranded / 25 mm2 flexible
  • 35 mm DIN rails acc. to EN 60715
  • thermoplastic, red, UL 94 V-0
  • indoor installation
  • IP 20
  • 1 module(s), DIN 43880
  • 117 g
  • 4013364127333
  • 1 pc(s)
  • 952 084
  • Specifications (PDF)
  • More

DEHNguard S VA FM

Basic circuit diagram DG S ... VA FMDimension drawing DG S ... VA FM

Modular single-pole surge arrester with a varistor connected in series with a spark gap in the pluggable protection module; with floating remote signalling contact.


Specifications

Type
Part No.
SPD according to EN 61643-11 / IEC 61643-11
Energy coordination with terminal equipment (≤ 10 m)
Nominal voltage (a.c.) (UN)
Max. continuous operating voltage (a.c.) (UC)
Max. continuous operating voltage (d.c.) (UC)
Nominal discharge current (8/20 µs) (In)
Max. discharge current (8/20 µs) (Imax)
Voltage protection level (UP)
Response time (tA)
Max. mains-side overcurrent protection
Short-circuit withstand capability for max. mains-side overcurrent protection (ISCCR)
Temporary overvoltage (TOV) (UT) – Characteristic
Operating temperature range (TU)
Operating state / fault indication
Number of ports
Cross-sectional area (min.)
Cross-sectional area (max.)
For mounting on
Enclosure material
Place of installation
Degree of protection
Capacity
Type of remote signalling contact
Switching capacity (a.c.)
Switching capacity (d.c.)
Cross-sectional area for remote signalling terminals
Weight
GTIN
PU
Part No.
  • DG S 75 VA FM
  • 952 085
  • type 2 / class II
  • type 2 + type 3
  • 60 V (50 / 60 Hz)
  • 75 V (50 / 60 Hz)
  • 100 V
  • 10 kA
  • 20 kA
  • ≤ 1.1 kV
  • ≤ 100 ns
  • 100 A gG
  • 25 kArms
  • 115 V / 120 min. – withstand
  • -40 °C ... +80 °C
  • green / red
  • 1
  • 1.5 mm2 solid / flexible
  • 35 mm2 stranded / 25 mm2 flexible
  • 35 mm DIN rail acc. to EN 60715
  • thermoplastic, red, UL 94 V-0
  • indoor installation
  • IP 20
  • 1 module(s), DIN 43880
  • changeover contact
  • 250 V / 0.5 A
  • 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
  • max. 1.5 mm2 solid / flexible
  • 111 g
  • 4013364127302
  • 1 pc(s)
  • 952 085
  • Specifications (PDF)
  • More
    • Further Pictures
      Basic circuit diagram
      open PDF
      Dimension drawing DG S 75 VA FM
      open PDF
      Further Information
      Product Specifications (Text)

      Back

      DEHNguard S 75 FM surge arrester
      Modular and pluggable single-pole surge arrester
      with remote signalling contact, width: 1 module
      Type 2 SPD according to EN 61643-11
      Leakage-current-free series connection of a varistor and a spark gap 
      Max. continuous operating voltage: 75 V a.c./100 V d.c.
      Voltage protection level: <= 1.1 kV
      Nominal discharge current: 10 kA
      Short-circuit strength: 25 kArms
      Energy-coordinated according to IEC 62305-4 
      with arresters of the Red/Line series
      Fault indication

      delivery and installation.

      Brand: DEHN
      Type: DG S 75 VA FM
      Part No.: 952 085

      or equivalent.
      Installation Instructions
      Certificates
      CE_DG_S_75_VA_FM
      CAD-Data for registered Users
      952090.stp
      952090.igs
      952090.jt
      952090.dwg
      952090m_E.dxf
  • DG S 275 VA FM
  • 952 087
  • type 2 / class II
  • type 2 + type 3
  • 230 V (50 / 60 Hz)
  • 275 V (50 / 60 Hz)
  • 350 V
  • 10 kA
  • 20 kA
  • ≤ 1.5 kV
  • ≤ 100 ns
  • 100 A gG
  • 25 kArms
  • 440 V / 120 min. – withstand
  • -40 °C ... +80 °C
  • green / red
  • 1
  • 1.5 mm2 solid / flexible
  • 35 mm2 stranded / 25 mm2 flexible
  • 35 mm DIN rail acc. to EN 60715
  • thermoplastic, red, UL 94 V-0
  • indoor installation
  • IP 20
  • 1 module(s), DIN 43880
  • changeover contact
  • 250 V / 0.5 A
  • 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
  • max. 1.5 mm2 solid / flexible
  • 116 g
  • 4013364127326
  • 1 pc(s)
  • 952 087
  • Specifications (PDF)
  • More
    • Further Pictures
      Basic circuit diagram DG S 275 VA FM
      open PDF
      Dimension drawing DG S 275 VA FM
      open PDF
      Further Information
      Product Specifications (Text)

      Back

      DEHNguard S275 VA FM surge arrester
      Modular and pluggable single-pole surge arrester
      with remote signalling contact, width: 1 module
      Type 2 SPD according to EN 61643-11
      Leakage-current-free series connection of a varistor and a spark gap 
      Max. continuous operating voltage: 275 V a.c./350 V d.c.
      Voltage protection level: <= 1.5 kV
      Nominal discharge current: 10 kA
      Short-circuit strength: 25 kArms
      Energy-coordinated according to IEC 62305-4 
      with arresters of the Red/Line series
      Fault indication

      delivery and installation.

      Brand: DEHN
      Type: DG S 275 VA FM
      Part No.: 952 087

      or equivalent.
      Installation Instructions
      Certificates
      CE_DG_S_275_VA_FM
      CAD-Data for registered Users
      952090.stp
      952090.igs
      952090.jt
      952090.dwg
      952090m_E.dxf
  • DG S 385 VA FM
  • 952 089
  • type 2 / class II
  • type 2 + type 3
  • 230 V (50 / 60 Hz)
  • 385 V (50 / 60 Hz)
  • 500 V
  • 10 kA
  • 20 kA
  • ≤ 1.75 kV
  • ≤ 100 ns
  • 100 A gG
  • 25 kArms
  • 440 V / 120 min. – withstand
  • -40 °C ... +80 °C
  • green / red
  • 1
  • 1.5 mm2 solid / flexible
  • 35 mm2 stranded / 25 mm2 flexible
  • 35 mm DIN rail acc. to EN 60715
  • thermoplastic, red, UL 94 V-0
  • indoor installation
  • IP 20
  • 1 module(s), DIN 43880
  • changeover contact
  • 250 V / 0.5 A
  • 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
  • max. 1.5 mm2 solid / flexible
  • 121 g
  • 4013364127340
  • 1 pc(s)
  • 952 089
  • Specifications (PDF)
  • More
    • Further Pictures
      Basic circuit diagram
      open PDF
      Dimension drawing DG S 385 VA FM
      open PDF
      Further Information
      Product Specifications (Text)

      Back

      DEHNguard S 385 VA FM surge arrester
      Modular and pluggable single-pole surge arrester
      with remote signalling contact, width: 1 module
      Type 2 SPD according to EN 61643-11
      Leakage-current-free series connection of a varistor and a spark gap 
      Max. continuous operating voltage: 385 V a.c./500 V d.c.
      Voltage protection level: <= 1.75 kV
      Nominal discharge current: 10 kA
      Short-circuit strength: 25 kArms
      Energy-coordinated according to IEC 62305-4 
      with arresters of the Red/Line series
      Fault indication

      delivery and installation.

      Brand: DEHN
      Type: DG S 385 VA FM
      Part No.: 952 089

      or equivalent.
      Installation Instructions
      Certificates
      CE_DG_S_385_VA_FM
      CAD-Data for registered Users
      952090.stp
      952090.igs
      952090.jt
      952090.dwg
      952090m_E.dxf

Accessories

DEHNpanel

Visual remote indicator for (multiple) surge protective devices (SPDs)

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Operating state/fault indication
Enclosure material
Weight
GTIN
PU
  • DPAN L
  • 910 200
  • green LED (flashing) / red LED (flashing)
  • noryl
  • 140 g
  • 4013364144019
  • 1 pc(s)
  • Specifications (PDF)
  • More
    • Further Pictures
      open PDF
      Further Information
      Product Specifications (Text)

      Back

      DPAN L visual remote indication for surge protective devices
      Visual remote indicator with current-saving LEDs for surge protective devices (SPDs) 
      With remote signalling contact
      Also suited for alarm signalling of other devices with floating changeover contact
      For installation in switchgear cabinet doors.
      Power supply: 2x 1.5 V AA batteries
      Degree of protection: IP 40
      Mounting dimensions: 92 x 45 mm
      Dimensions: 96 x 48 x 75 mm

      delivery and installation.

      Brand: DEHN
      Type: DPAN L
      Part No.: 910 200

      or equivalent.
      Installation Instructions
      Certificates
      CE_DEHNpanel

Varistor-Based Protection Module for DEHNguard S ... VA

Protection module for DEHNguard S ... VA arresters comprising a varistor connected in series with a spark gap.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Max. continuous operating voltage (a.c.) (UC)
Weight
GTIN
PU

STAK 25 Pin-shaped Terminal

Allows series connection (connection of two conductors) of surge protective devices up to 25 mm2.
Allows EMC-optimised feed-through wiring according to IEC 60364-5-53.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Nominal a.c./d.c. voltage (UN)
Nominal load current a.c. (IL)
Lightning impulse current (10/350 µs)
Weight
GTIN
PU

STAK 3X16 Pin-shaped Terminal

Pin-shaped terminal for EMC-optimised series connection of lightning current and surge arresters according to IEC 60364-5-53.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Weight
GTIN
PU