DEHNprotector

Adapter with integrated Surge Protection

The adapter protects the power supply circuits of electronic equipment against transients and high-frequency interference voltages (DEHNpro 230 F Protector). For installation in conformity with the lightning protection zone concept at the boundaries from 1 – 2 and higher.
  • Surge protection with monitoring device and disconnector
  • Visual operating state (green) and fault indication (red)
  • Mains filter (DEHNpro 230 F Protector only)
  • Enhanced safety due to fault-proof Y protective circuit

Version

DEHNpro 230: Protection of terminal equipment
DEHNpro 230 F: Protection of terminal equipment with mains filter

Details

The adapters with integrated surge protection of the DEHNpro family protect electronic loads connected to final circuits from overvoltage. An interference suppressor filter with a balancing and unbalancing effect was integrated in the powerful surge protective circuit of DEHNpro 230 F Protectors. This combination of surge protection and filter prevents a core saturation of the filter in case of high-level transients. The nominal current carrying capability of 16 A (DEHNpro 230) and 10 A (230 F Protector) allows flexible use of these devices in final circuits. The fault-proof Y circuit ensures protection even if the phase and neutral conductors in standard earthed socket outlets cannot be identified. The integrated disconnector ensures reliability of devices and installations. The standard green and red LEDs indicate the operating state of the surge protective devices.
The modern design of the DEHNpro devices and the use of high-quality materials ensure safety in a sophisticated appearance. The DEHNpro devices thus ideally adapt to the installation environment. They create the right technical environment already at the socket outlet for connecting the latest communication and multimedia systems. The curved enclosure surfaces and the smooth surface structure ensure that the DEHNpro devices will not lose their original properties even after several years of application.

Models

DPRO 230 Protector

DPRO 230 F Protector

DPRO 230 Protector

Basic circuit diagram DPRO 230Dimension drawing DPRO 230

Adapter with integrated surge protection and child lock.


Specifications

Type
Part No.
SPD according to EN 61643-11 / IEC 61643-11
Nominal voltage (a.c.) (UN)
Max. continuous operating voltage (a.c.) (UC)
Nominal load current (a.c.) (IL)
Nominal discharge current (8/20 µs) (In)
Total discharge current (8/20 µs) [L+N-PE] (Itotal)
Combination wave (UOC)
Combination wave [L+N-PE] (UOC total)
Voltage protection level [L-N] / [L/N-PE] (UP)
Response time [L-N] (tA)
Response time [L/N-PE] (tA)
Max. mains-side overcurrent protection
Short-circuit withstand capability for max. mains-side overcurrent protection (ISCCR)
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic
Temporary overvoltage (TOV) [L/N-PE] (UT) – Characteristic
Temporary overvoltage (TOV) [L/N-PE] (UT) – Characteristic
Temporary overvoltage (TOV) [L+N-PE] (UT) – Characteristic
Fault indication
Operating state indication
Number of ports
Operating temperature range (TU)
For mounting on
Enclosure material
Place of installation
Degree of protection
Dimensions
Weight
GTIN
PU
Part No.
  • DPRO 230
  • 909 230
  • type 3 / class III
  • 230 V (50 / 60 Hz)
  • 255 V (50 / 60 Hz)
  • 16 A
  • 3 kA
  • 5 kA
  • 6 kV
  • 10 kV
  • ≤ 1250 / ≤ 1500 V
  • ≤ 25 ns
  • ≤ 100 ns
  • B 16 A
  • 1 kArms
  • 335 V / 5 sec. – withstand
  • 440 V / 120 min. – safe failure
  • 335 V / 120 min. – withstand
  • 440 V / 5 sec. – withstand
  • 1200 V + UREF / 200 ms – safe failure
  • red light
  • green light
  • 1
  • -25 °C ... +40 °C
  • earthed socket outlets DIN 49440 / DIN 49441
  • thermoplastic, pure white, UL 94 V-2
  • indoor installation
  • IP 20
  • 126 x 69 x 41 mm
  • 190 g
  • 4013364117686
  • 1 pc(s)
  • 909 230
  • Specifications (PDF)
  • More
    • Further Pictures
      Basic circuit diagram DPRO 230
      open PDF
      Dimension drawing DPRO 230
      open PDF
      Further Information
      Product Specifications (Text)

      Back

      DEHNprotector 230 surge protective adapter
      Surge protective adapter for protecting the power supply circuit 
      of electronic devices against transient overvoltage
      Type 3 SPD according to EN 61643-11
      Visual operating state and fault indication
      Max. continuous operating voltage: 255 V a.c.
      Voltage protection level: <= 1.5 kV
      Total discharge current: 5 kA
      Max. mains-side overcurrent protection: 
      16 A gG or B 16 A
      Energy-coordinated according to IEC 62305-4 with arresters 
      of the Red/Line series

      delivery and installation.

      Brand: DEHN
      Type: DPRO 230
      Part No.: 909 230

      or equivalent.
      Installation Instructions
      Certificates
      CE_DPRO_230
      CAD-Data for registered Users
      909230_240m_D.dxf

DPRO 230 F Protector

Basic circuit diagram DPRO 230 FDimension drawing DPRO 230 F

Adapter with integrated surge protection, mains filter and child lock.


Specifications

Type
Part No.
SPD according to EN 61643-11 / IEC 61643-11
Nominal voltage (a.c.) (UN)
Max. continuous operating voltage (a.c.) (UC)
Nominal load current (a.c.) (IL)
Voltage drop in percent [L'/N'-N'/L' / L/N-N/L] for UC/IL (∆U)
Nominal discharge current (8/20 µs) (In)
Total discharge current (8/20 µs) [L+N-PE] (Itotal)
Combination wave (UOC)
Combination wave [L+N-PE] (UOC total)
Voltage protection level [L-N] / [L/N-PE] (UP)
Response time [L-N] (tA)
Response time [L/N-PE] (tA)
Max. mains-side overcurrent protection
Short-circuit withstand capability for max. mains-side overcurrent protection (ISCCR)
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic
Temporary overvoltage (TOV) [L/N-PE] (UT) – Characteristic
Temporary overvoltage (TOV) [L/N-PE] (UT) – Characteristic
Temporary overvoltage (TOV) [L+N-PE] (UT) – Characteristic
Fault indication
Operating state indication
Number of ports
Operating temperature range (TU)
For mounting on
Enclosure material
Place of installation
Degree of protection
Dimensions
Mains filter
Attenuation for f = 1 MHz, balanced
Attenuation for f = 1 MHz, unbalanced
Weight
GTIN
PU
Part No.
  • DPRO 230 F
  • 909 240
  • type 3 / class III
  • 230 V (50 / 60 Hz)
  • 255 V (50 / 60 Hz)
  • 10 A
  • ≤ 0.3 %
  • 3 kA
  • 5 kA
  • 6 kV
  • 10 kV
  • ≤ 1250 / ≤ 1500 V
  • ≤ 25 ns
  • ≤ 100 ns
  • B 16 A
  • 1 kArms
  • 335 V / 5 sec. – withstand
  • 440 V / 120 min. – safe failure
  • 335 V / 120 min. – withstand
  • 440 V / 5 sec. – withstand
  • 1200 V + UREF / 200 ms – safe failure
  • red light
  • green light
  • 2
  • -25 °C ... +40 °C
  • earthed socket outlets DIN 49440 / DIN 49441
  • thermoplastic, pure white, UL 94 V-2
  • indoor installation
  • IP 20
  • 126 x 69 x 41 mm
  • acc. to EN 60939-1 (DIN VDE 0565-3)
  • ≥ 40 dB
  • ≥ 30 dB
  • 194 g
  • 4013364117693
  • 1 pc(s)
  • 909 240
  • Specifications (PDF)
  • More
    • Further Pictures
      Basic circuit diagram DPRO 230 F
      open PDF
      Dimension drawing DPRO 230 F
      open PDF
      Further Information
      Product Specifications (Text)

      Back

      DEHNprotector 230 F surge protective adapter with mains filter
      Surge protective adapter for protecting the power supply circuit 
      of electronic devices against transient overvoltage
      Type 3 SPD according to EN 61643-11
      Visual operating state and fault indication
      Mains filter according to DIN VDE 0565 Part 3
      Max. continuous operating voltage: 255 V a.c.
      Voltage protection level: <= 1.5 kV
      Total discharge current: 5 kA
      Max. mains-side overcurrent protection: 
      16 A gG or B 16 A
      Energy-coordinated according to IEC 62305-4 with arresters 
      of the Red/Line series

      delivery and installation.

      Brand: DEHN
      Type: DPRO 230 F
      Part No.: 909 240

      or equivalent.
      Installation Instructions
      Certificates
      CE_DPRO_230_F
      CE_DPRO_230_F
      CAD-Data for registered Users
      909230_240m_D.dxf