PHE4 Voltage Detector Nominal Voltage 30 ... 420 kV

Details

PHE4 voltage detector applied in a 110 kV outdoor switching station.
  • High nominal voltage range
  • Unique plug-in coupling system
  • Integrated visual and acoustic indication
  • Also for use in wet weather conditions

Models

Nominal Voltage Range 30 ... 132 kV / 50 Hz, M12 Thread

Nominal Voltage Range 110 ... 132 kV / 50 & 16.7 Hz, M12 Thread

Nominal Voltage Ranges 110 ... 420 kV / 50 Hz, M12 Thread

Nominal Voltage Range 30 ... 132 kV / 50 Hz, M12 Thread

Category "S" for switchgear installations and overhead lines.


Specifications

Type
Part No.
Nominal voltage (UN)
Type of voltage
Frequency
Category
Total length (lG)
Insertion depth (lO)
Length (handle) (lH)
Standard
Temperature range
Design
For use in wet weather conditions
For
Application
Design
Indication
Sound level
Self-testing element *)
Battery
Material (test electrode)
Material (test prod)
Material (indicator)
Material (insulating stick)
Diameter (insulating stick)
Weight
GTIN
PU
Part No.
*) all circuits without test prod
  • PHE4 30 60 S
  • 783 270
  • 30 ... 60 kV
  • a.c.
  • 50 Hz
  • S
  • 2560 mm
  • 910 mm
  • 780 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 2,48 kg
  • 4013364309852
  • 1 pc(s)
  • 783 270
  • Specifications (PDF)
  • More
  • PHE4 60 110 S
  • 783 275
  • 60 ... 110 kV
  • a.c.
  • 50 Hz
  • S
  • 3010 mm
  • 910 mm
  • 780 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 2,91 kg
  • 4013364309845
  • 1 pc(s)
  • 783 275
  • Specifications (PDF)
  • More
  • PHE4 60 132 S
  • 783 280
  • 60 ... 132 kV
  • a.c.
  • 50 Hz
  • S
  • 3420 mm
  • 910 mm
  • 780 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 3,31 kg
  • 4013364317284
  • 1 pc(s)
  • 783 280
  • Specifications (PDF)
  • More

Nominal Voltage Range 110 ... 132 kV / 50 & 16.7 Hz, M12 Thread

Category "S" for switchgear installations and overhead lines.


Specifications

Type
Part No.
Nominal voltage (UN)
Type of voltage
Frequency
Category
Total length (lG)
Insertion depth (lO)
Length (handle) (lH)
Standard
Temperature range
Design
For use in wet weather conditions
For
Application
Design
Indication
Sound level
Self-testing element *)
Battery
Material (test electrode)
Material (test prod)
Material (indicator)
Material (insulating stick)
Diameter (insulating stick)
Weight
GTIN
PU
Part No.
*) all circuits without test prod
  • PHE4 110 132 S 16.7 50
  • 783 460
  • 110 ... 132 kV
  • a.c.
  • 50 & 16.7 Hz
  • S
  • 3420 mm
  • 910 mm
  • 780 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 3,31 kg
  • 4013364309869
  • 1 pc(s)
  • 783 460
  • Specifications (PDF)
  • More

Nominal Voltage Ranges 110 ... 420 kV / 50 Hz, M12 Thread

Category "S" for switchgear installations and overhead lines.


Specifications

Type
Part No.
Nominal voltage (UN)
Type of voltage
Frequency
Category
Total length (lG)
Insertion depth (lO)
Standard
Temperature range
Design
For use in wet weather conditions
For
Application
Design
Indication
Sound level
Self-testing element *)
Battery
Material (test electrode)
Material (test prod)
Material (indicator)
Material (insulating stick)
Diameter (insulating stick)
Weight
GTIN
PU
Part No.
*) all circuits without test prod
  • PHE4 110 220 S
  • 783 285
  • 110 ... 220 kV
  • a.c.
  • 50 Hz
  • S
  • 4420 mm
  • 910 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 3,8 kg
  • 4013364316898
  • 1 pc(s)
  • 783 285
  • Specifications (PDF)
  • More
  • PHE4 220 420 S
  • 783 290
  • 220 ... 420 kV
  • a.c.
  • 50 Hz
  • S
  • 5750 mm
  • 910 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 5,56 kg
  • 4013364316904
  • 1 pc(s)
  • 783 290
  • Specifications (PDF)
  • More

Accessories

Adapter (plug-in Coupling / T Pin Shaft)

For extending the handle of IS ... STK insulating sticks using an ES SQ or ES SQL earthing stick.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Total length (lG)
Weight
GTIN
PU

STK End Fitting

For use as termination and protection.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Total length (lG)
Diameter
Weight
GTIN
PU

STK End Fitting with Eye

For use as protection and transport eye for work on overhead lines.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Total length (lG)
Diameter
Weight
GTIN
PU

Universal Plastic Case for PHE4, PHE III, PHV and PHV I

With aluminium frame and convoluted foam.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Suitable for
Dimensions
Colour
Weight
GTIN
PU
  • KKL 127 28 12
  • 766 995
  • Voltage detector PHE4, PHE III, PHE, phase comparator PHV
  • 1270 x 280 x 126 mm
  • black ●
  • 4,38 kg
  • 4013364247147
  • 1 pc(s)
  • Specifications (PDF)
  • More

Artificial Leather Bag, empty


Specifications

Type
Part No.
Suitable for
Colour
Dimensions
Weight
GTIN
PU

Artificial Leather Bag for PHE4 and PHE


Specifications

Type
Part No.
Suitable for
Dimensions
Colour
DB drawing No.
Weight
GTIN
PU