DPL 10 G3

Surge Arrester

Pluggable arresters for use in LSA systems of the 2/10 series.For use as protection block for 10 pairs with individuallyexchangeableprotection elements.
  • Suitable for disconnection or terminal blocks of LSA systems of the 2/10 series
  • Equipped with individually tested gas discharge tubes for ten pairs
  • Individually exchangeable protection elements (gas discharge tubes)

Description

Pluggable surge arresters for use as protection blocks in IT systems and devices which have to be connected via terminal or disconnection blocks using the LSA insulation displacement method. Installation onto terminal blocks, however, is the preferred method, as their contact forces provide better fixation – even in case of slight vibrations.
The surge arresters for 10 pairs can be easily installed and removed for testing purposes. Contact to earth via the mounting frame is automatically established as soon as the arrester is plugged in. After being overloaded, the protection elements can be individually replaced.

Detail 1

DPL 10 G3 family
The protection blocks consist of similar basic SPD blocks equipped and tested with different protection elements according to needs.
DPL 10 G3:
10 standard gas discharge tubes
DPL 10 G3 FSD:
10 gas discharge tubes with fail-safe function and visual indication

Detail 2

Installation of DPL

Models

DPL 10 G3

DPL 10 G3

Basic circuit diagram DPL 10 G3Dimension drawing DPL 10 G3

Plug-in SPD block for ten pairs with three-pole gas discharge tubes for almost all applications. FSD arresters feature a fail-safe function and an additional visual indication when the fail-safe function has been activated. Thus it can be immediately identified whether an arrester has to be replaced.


Specifications

Type
Part No.
SPD class
Fault indication
Nominal voltage (UN)
Max. continuous operating voltage (d.c.) (Uc)
Max. continuous operating voltage (a.c.) (Uc)
Nominal current (IL)
C2 Total nominal discharge current (8/20 µs) (In)
C2 Nominal discharge current (8/20 µs) per line (In)
Voltage protection level line-line for In C2 (UP)
Voltage protection level line-PG for In C2 (Up)
Voltage protection level line-line for 1 kV/µs C3 (Up)
Voltage protection level line-PG for 1 kV/µs (Up)
Capacitance line-line (C)
Capacitance line-PG (C)
Fail-safe function
Operating temperature range (TU)
Pluggable into
Earthing via
Enclosure material
Colour
Test standards
Approvals
Weight
GTIN
PU
Part No.
  • DPL 10 G3 110
  • 907 214
  • B
  •  
  • 110 V
  • 180 V
  • 127 V
  • 0.4 A
  • 10 kA
  • 5 kA
  • ≤ 600 V
  • ≤ 600 V
  • ≤ 600 V
  • ≤ 600 V
  • ≤ 5 pF
  • ≤ 5 pF
  •  
  • -40 °C ... +80 °C
  • LSA disconnection and terminal blocks (type 2)
  • mounting frame
  • polyamide
  • grey
  • IEC 61643-21 / EN 61643-21
  • EAC
  • 66 g
  • 4013364100879
  • 1 pc(s)
  • 907 214
  • Specifications (PDF)
  • More
  • DPL 10 G3 110 FSD
  • 907 216
  • B
  • visual, colour change
  • 110 V
  • 180 V
  • 127 V
  • 0.4 A
  • 10 kA
  • 5 kA
  • ≤ 600 V
  • ≤ 600 V
  • ≤ 600 V
  • ≤ 600 V
  • ≤ 5 pF
  • ≤ 5 pF
  • gas discharge tube with spring contacts
  • -40 °C ... +80 °C
  • LSA disconnection and terminal blocks (type 2)
  • mounting frame
  • polyamide
  • grey
  • IEC 61643-21 / EN 61643-21
  • EAC
  • 66 g
  • 4013364106680
  • 1 pc(s)
  • 907 216
  • Specifications (PDF)
  • More
    • Further Pictures
      Basic circuit diagram DPL 10 G3 110 FSD
      open PDF
      Dimension drawing DPL 10 G3 110 FSD
      open PDF
      Further Information
      Product Specifications (Text)

      Back

      DPL 10 G3 110 FSD plug-in SPD block for 10 pairs
      DPL 10 G3 110 FSD surge arrester protection block  
      For LSA Plus technology, series 2
      With fail-safe technology and visual fault indication 
      by colour change for protecting 10 pairs of telecommunication systems
      Nominal discharge current:(8/20) 10 kA/pair
      Nominal voltage: 110 V a.c.
      Max. continuous operating voltage: 180 V d.c.

      delivery and installation.

      Brand: DEHN
      Type: DPL 10 G3 110 FSD
      Part No.: 907 216

      or equivalent.
      Installation Instructions
      Certificates
      CE_DPL_10_G3_110_FSD

Accessories

Gas Discharge Tube

High-capacity replacement gas discharge tubes for DPL 10 G3. Three-pole version with common arcing chamber for a constant voltage protection level line-line and line-ground.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Integrated into Part No.
Visual fault indication
Fail-safe spring
Weight
GTIN
PU
  • GDT 230 G3 FSD
  • 907 217
  • 907 216
  • yes
  • yes
  • 2 g
  • 4013364107342
  • 1 pc(s)
  • Specifications (PDF)
  • More
    • Further Pictures
      Further Information
      Product Specifications (Text)

      Back

      GDT 230 G3 FSD gas discharge tube
      Gas discharge tube for DPL 10 G3, three-pole, 
      with a single arcing chamber and fail-safe spring contact,
      visual fault indicator (colour change)

      delivery and installation.

      Brand: DEHN
      Type: GDT 230 G3 FSD
      Part No.: 907 217

      or equivalent.
      Certificates
      CE_SPD_Blockmagazine_DPL.pdf