PHE4 Voltage Detector Nominal Voltage 1 ... 36 kV

Details

PHE4 voltage detector with visual and acoustic indication.
  • Self-test of all live parts including test prod
  • Unique plug-in coupling system
  • Integrated visual and acoustic indication
  • Also for use in wet weather conditions

Models

Nominal Voltages up to 30 kV / 50 Hz, M12 Thread

Nominal Voltages up to 36 kV / 50 Hz, M12 Thread

Nominal Voltages up to 36 kV / 50 Hz, switchable, M12 Thread

Nominal Voltages up to 30 kV / 50 Hz, Gear Coupling

Nominal Voltages up to bis 30 kV / 50 Hz, Gear Coupling

Nominal Voltages up to 36 kV / 60 Hz, M12 Thread

Nominal Voltage up to 20 kV / 50 Hz or 16.7 Hz, switchable

Nominal Voltage up to 20 kV / 16.7 Hz, M12 Thread

Nominal Voltages up to 30 kV / 50 Hz, M12 Thread

Category "S" for switchgear installations and overhead lines.


Specifications

Type
Part No.
Nominal voltage (UN)
Type of voltage
Frequency
Category
Total length (lG)
Insertion depth (lO)
Length (handle) (lH)
Standard
Temperature range
Design
For use in wet weather conditions
For
Application
Design
Indication
Sound level
Self-testing element *)
Battery
Material (test electrode)
Material (test prod)
Material (indicator)
Material (insulating stick)
Diameter (insulating stick)
Weight
GTIN
PU
Part No.
*) all circuits including test prod
  • PHE4 3 S
  • 783 003
  • 3 kV
  • a.c.
  • 50 Hz
  • S
  • 1030 mm
  • 230 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,24 kg
  • 4013364310179
  • 1 pc(s)
  • 783 003
  • Specifications (PDF)
  • More
  • PHE4 6 S
  • 783 006
  • 6 kV
  • a.c.
  • 50 Hz
  • S
  • 1030 mm
  • 230 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,27 kg
  • 4013364310155
  • 1 pc(s)
  • 783 006
  • Specifications (PDF)
  • More
  • PHE4 10 S
  • 783 010
  • 10 kV
  • a.c.
  • 50 Hz
  • S
  • 1030 mm
  • 230 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,23 kg
  • 4013364297869
  • 1 pc(s)
  • 783 010
  • Specifications (PDF)
  • More
  • PHE4 20 S
  • 783 020
  • 20 kV
  • a.c.
  • 50 Hz
  • S
  • 1200 mm
  • 400 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,35 kg
  • 4013364310124
  • 1 pc(s)
  • 783 020
  • Specifications (PDF)
  • More
  • PHE4 30 S
  • 783 030
  • 30 kV
  • a.c.
  • 50 Hz
  • S
  • 1720 mm
  • 920 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,62 kg
  • 4013364310100
  • 1 pc(s)
  • 783 030
  • Specifications (PDF)
  • More

Nominal Voltages up to 36 kV / 50 Hz, M12 Thread

Category "S" for switchgear installations and overhead lines.


Specifications

Type
Part No.
Nominal voltage (UN)
Type of voltage
Frequency
Category
Total length (lG)
Insertion depth (lO)
Length (handle) (lH)
Standard
Temperature range
Design
For use in wet weather conditions
For
Application
Design
Indication
Sound level
Self-testing element *)
Battery
Material (test electrode)
Material (test prod)
Material (indicator)
Material (insulating stick)
Diameter (insulating stick)
Weight
GTIN
PU
Part No.
*) all circuits including test prod
  • PHE4 1 3 S
  • 783 013
  • 1 ... 3 kV
  • a.c.
  • 50 Hz
  • S
  • 1410 mm
  • 610 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,47 kg
  • 4013364310186
  • 1 pc(s)
  • 783 013
  • Specifications (PDF)
  • More
  • PHE4 3 10 S
  • 783 231
  • 3 ... 10 kV
  • a.c.
  • 50 Hz
  • S
  • 1410 mm
  • 610 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,46 kg
  • 4013364310087
  • 1 pc(s)
  • 783 231
  • Specifications (PDF)
  • More
  • PHE4 6 20 S
  • 783 235
  • 6 ... 20 kV
  • a.c.
  • 50 Hz
  • S
  • 1600 mm
  • 800 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,55 kg
  • 4013364310049
  • 1 pc(s)
  • 783 235
  • Specifications (PDF)
  • More
  • PHE4 10 20 S
  • 783 240
  • 10 ... 20 kV
  • a.c.
  • 50 Hz
  • S
  • 1410 mm
  • 610 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,46 kg
  • 4013364310056
  • 1 pc(s)
  • 783 240
  • Specifications (PDF)
  • More
  • PHE4 10 30 S
  • 783 250
  • 10 ... 30 kV
  • a.c.
  • 50 Hz
  • S
  • 1720 mm
  • 920 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,61 kg
  • 4013364309999
  • 1 pc(s)
  • 783 250
  • Specifications (PDF)
  • More
  • PHE4 20 36 S
  • 783 245
  • 20 ... 36 kV
  • AC
  • 50 Hz
  • S
  • 1720 mm
  • 920 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Cu alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,61 kg
  • 4013364310032
  • 1 pc(s)
  • 783 245
  • Specifications (PDF)
  • More

Nominal Voltages up to 36 kV / 50 Hz, switchable, M12 Thread

Category "S" for switchgear installations and overhead lines.


Specifications

Type
Part No.
Nominal voltage (UN)
Type of voltage
Frequency
Category
Total length (lG)
Insertion depth (lO)
Length (handle) (lH)
Standard
Temperature range
Design
For use in wet weather conditions
For
Application
Design
Indication
Sound level
Self-testing element *)
Battery
Material (test electrode)
Material (test prod)
Material (indicator)
Material (insulating stick)
Diameter (insulating stick)
Weight
GTIN
PU
Part No.
*) all circuits including test prod
  • PHE4 U 2 20 S
  • 783 520
  • 2 ... 6 / 6 ... 20  kV
  • a.c.
  • 50 Hz
  • S
  • 1600 mm
  • 800 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,55 kg
  • 4013364309913
  • 1 pc(s)
  • 783 520
  • Specifications (PDF)
  • More
  • PHE4 U 3 30 S
  • 783 530
  • 3 ... 10 / 10 ... 30  kV
  • a.c.
  • 50 Hz
  • S
  • 1720 mm
  • 920 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,61 kg
  • 4013364309968
  • 1 pc(s)
  • 783 530
  • Specifications (PDF)
  • More
  • PHE4 U 6 36 S
  • 783 536
  • 6 ... 15 / 15 ... 36  kV
  • a.c.
  • 50 Hz
  • S
  • 1720 mm
  • 920 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,61 kg
  • 4013364309944
  • 1 pc(s)
  • 783 536
  • Specifications (PDF)
  • More

Nominal Voltages up to 30 kV / 50 Hz, Gear Coupling

Category "S" for switchgear installations and overhead lines.


Specifications

Type
Part No.
Nominal voltage (UN)
Type of voltage
Frequency
Category
Total length (lG)
Insertion depth (lO)
Length (handle) (lH)
Standard
Temperature range
Design
For use in wet weather conditions
For
Application
Design
Indication
Sound level
Self-testing element *)
Battery
Material (test electrode)
Material (test prod)
Material (indicator)
Material (insulating stick)
Diameter (insulating stick)
Weight
GTIN
PU
Part No.
*) all circuits including test prod
  • PHE4 3 S ZK
  • 783 103
  • 3 kV
  • a.c.
  • 50 Hz
  • S
  • 1070 mm
  • 230 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,27 kg
  • 4013364317277
  • 1 pc(s)
  • 783 103
  • Specifications (PDF)
  • More
  • PHE4 6 S ZK
  • 783 106
  • 6 kV
  • a.c.
  • 50 Hz
  • S
  • 1070 mm
  • 230 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,27 kg
  • 4013364317260
  • 1 pc(s)
  • 783 106
  • Specifications (PDF)
  • More
  • PHE4 10 S ZK
  • 783 110
  • 10 kV
  • a.c.
  • 50 Hz
  • S
  • 1070 mm
  • 230 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,27 kg
  • 4013364317253
  • 1 pc(s)
  • 783 110
  • Specifications (PDF)
  • More
  • PHE4 20 S ZK
  • 783 120
  • 20 kV
  • a.c.
  • 50 Hz
  • S
  • 1240 mm
  • 400 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,35 kg
  • 4013364317246
  • 1 pc(s)
  • 783 120
  • Specifications (PDF)
  • More
  • PHE4 30 S ZK
  • 783 130
  • 30 kV
  • a.c.
  • 50 Hz
  • S
  • 1760 mm
  • 920 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,61 kg
  • 4013364317239
  • 1 pc(s)
  • 783 130
  • Specifications (PDF)
  • More

Nominal Voltages up to bis 30 kV / 50 Hz, Gear Coupling

Category "S" for switchgear installations and overhead lines.


Specifications

Type
Part No.
Nominal voltage (UN)
Type of voltage
Frequency
Category
Total length (lG)
Insertion depth (lO)
Length (handle) (lH)
Standard
Temperature range
Design
For use in wet weather conditions
For
Application
Design
Indication
Sound level
Self-testing element *)
Battery
Material (test electrode)
Material (test prod)
Material (indicator)
Material (insulating stick)
Diameter (insulating stick)
Weight
GTIN
PU
Part No.
*) all circuits including test prod
  • PHE4 3 10 S ZK
  • 783 141
  • 3 ... 10 kV
  • a.c.
  • 50 Hz
  • S
  • 1450 mm
  • 610 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,46 kg
  • 4013364317222
  • 1 pc(s)
  • 783 141
  • Specifications (PDF)
  • More
  • PHE4 6 20 S ZK
  • 783 151
  • 6 ... 20 kV
  • a.c.
  • 50 Hz
  • S
  • 1640 mm
  • 800 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,55 kg
  • 4013364317215
  • 1 pc(s)
  • 783 151
  • Specifications (PDF)
  • More
  • PHE4 10 30 S ZK
  • 783 161
  • 10 ... 30 kV
  • a.c.
  • 50 Hz
  • S
  • 1760 mm
  • 920 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,61 kg
  • 4013364317208
  • 1 pc(s)
  • 783 161
  • Specifications (PDF)
  • More

Nominal Voltages up to 36 kV / 60 Hz, M12 Thread

Category "S" for switchgear installations and overhead lines.


Specifications

Type
Part No.
Nominal voltage (UN)
Type of voltage
Frequency
Category
Total length (lG)
Insertion depth (lO)
Length (handle) (lH)
Standard
Temperature range
Design
For use in wet weather conditions
For
Application
Design
Indication
Sound level
Self-testing element *)
Battery
Material (test electrode)
Material (test prod)
Material (indicator)
Material (insulating stick)
Diameter (insulating stick)
Weight
GTIN
PU
Part No.
*) all circuits including test prod
  • PHE4 3 10 S 60
  • 783 332
  • 3 ... 10 kV
  • a.c.
  • 60 Hz
  • S
  • 1410 mm
  • 610 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,46 kg
  • 4013364310070
  • 1 pc(s)
  • 783 332
  • Specifications (PDF)
  • More
  • PHE4 6 20 S 60
  • 783 335
  • 6 ... 20 kV
  • a.c.
  • 60 Hz
  • S
  • 1600 mm
  • 800 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,55 kg
  • 4013364310001
  • 1 pc(s)
  • 783 335
  • Specifications (PDF)
  • More
  • PHE4 10 30 S 60
  • 783 345
  • 10 ... 30 kV
  • a.c.
  • 60 Hz
  • S
  • 1720 mm
  • 920 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,61 kg
  • 4013364309975
  • 1 pc(s)
  • 783 345
  • Specifications (PDF)
  • More
  • PHE4 20 36 S 60
  • 783 342
  • 20 ... 36 kV
  • a.c.
  • 60 Hz
  • S
  • 1720 mm
  • 920 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,61 kg
  • 4013364310025
  • 1 pc(s)
  • 783 342
  • Specifications (PDF)
  • More
  • PHE4 U 3 36 S 60
  • 783 395
  • 3 ... 10 / 12 ... 36  kV
  • a.c.
  • 60 Hz
  • S
  • 1720 mm
  • 920 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,61 kg
  • 4013364309951
  • 1 pc(s)
  • 783 395
  • Specifications (PDF)
  • More

Nominal Voltage up to 20 kV / 50 Hz or 16.7 Hz, switchable

Category "S" for switchgear installations and overhead lines.


Specifications

Type
Part No.
Nominal voltage (UN)
Type of voltage
Frequency
Category
Total length (lG)
Insertion depth (lO)
Length (handle) (lH)
Standard
Temperature range
Design
For use in wet weather conditions
For
Application
Design
Indication
Sound level
Self-testing element *)
Battery
Material (test electrode)
Material (test prod)
Material (indicator)
Material (insulating stick)
Diameter (insulating stick)
Weight
GTIN
PU
Part No.
*) all circuits including test prod
  • PHE4 U 6 20 S 16.7 50
  • 783 430
  • 6 ... 20 kV
  • a.c.
  • 50 / 16.7 Hz
  • S
  • 1600 mm
  • 800 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,55 kg
  • 4013364309906
  • 1 pc(s)
  • 783 430
  • Specifications (PDF)
  • More

Nominal Voltage up to 20 kV / 16.7 Hz, M12 Thread

Category "S" for switchgear installations and overhead lines.


Specifications

Type
Part No.
Nominal voltage (UN)
Type of voltage
Frequency
Category
Total length (lG)
Insertion depth (lO)
Length (handle) (lH)
Standard
Temperature range
Design
For use in wet weather conditions
For
Application
Design
Indication
Sound level
Self-testing element *)
Battery
Material (test electrode)
Material (test prod)
Material (indicator)
Material (insulating stick)
Diameter (insulating stick)
Weight
GTIN
PU
Part No.
*) all circuits including test prod
  • PHE4 6 20 S 16.7
  • 783 420
  • 6 ... 20 kV
  • a.c.
  • 16.7 Hz
  • S
  • 1600 mm
  • 800 mm
  • 265 mm
  • EN/IEC 61243-1 (DIN VDE 0682-411)
  • –25 °C ... +70 °C, climatic category N and W
  • Complete
  • Yes
  • Indoor and outdoor installations
  • Switchgear installations and overhead lines
  • Single-pole
  • Acoustic and visual
  • > 67 dB(A) (visual indication and intermittent sound signal)
  • Yes
  • Lithium AA 1.5 Volt
  • Copper alloy/gal Sn
  • Glass-fibre reinforced epoxy resin tube
  • Plastic, fully insulated
  • Glass-fibre reinforced polyester tube
  • 30 mm
  • 1,55 kg
  • 4013364309890
  • 1 pc(s)
  • 783 420
  • Specifications (PDF)
  • More

Accessories

Onion-shaped Electrode

For contacting varnished busbars.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Nominal voltage (UN)
Material
Weight
GTIN
PU

Pin-shaped Electrode

For contacting varnished busbars.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Nominal voltage up to (UN)
Material
Weight
GTIN
PU

V-shaped Electrode

For contacting round conductors.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Nominal voltage (UN)
Material
Weight
GTIN
PU

Hook-shaped Electrode

For contacting overhead line conductors.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Field of application
Material
Weight
GTIN
PU

Fork-shaped Electrode

For contacting overhead line conductors.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Field of application
Material
Weight
GTIN
PU

Eaton Holec Magnefix Electrode

For Eaton Holec Magnefix switchgear installations of type MA, MD4, MF, MG, MY.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Nominal voltage (UN)
Length
Material
Weight
GTIN
PU

Straight Test Probe

For switchgear installations with limited access (e.g. Calor Emag/Isopond and Krone/KES).
Not suitable for use in wet weather conditions

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Nominal voltage (UN)
Total length (lG)
Length (l1)
Diameter
For use at
Weight
GTIN
PU

Straight Test Prod, 800 mm

For substations and switchgear installations that require a greater insertion depth.
Not suitable for use in wet weather conditions

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Nominal voltage (UN)
Total length (IG)
Diameter
For use at
Weight
GTIN
PU

25° angled Test Probe

For switchgear installations with limited access.
Not suitable for use in wet weather conditions

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Nominal voltage (UN)
Total length (lG)
Length (l1)
Diameter
For use at
Weight
GTIN
PU

45° angled Test Probe

For switchgear installations with limited access.
Not suitable for use in wet weather conditions

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Nominal voltage (UN)
Total length (lG)
Length (l1)
Diameter
For use at
Weight
GTIN
PU

90° angled Test Probe

For switchgear installations with limited access and remotely situated contacts.
Not suitable for use in wet weather conditions

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Nominal voltage (UN)
Total length (lG)
Length (l1)
Diameter
For use at
Weight
GTIN
PU

Adapter (plug-in Coupling / T Pin Shaft)

For extending the handle of IS ... STK insulating sticks using an ES SQ or ES SQL earthing stick.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Total length (lG)
Weight
GTIN
PU

STK End Fitting

For use as termination and protection.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Total length (lG)
Diameter
Weight
GTIN
PU

STK End Fitting with Eye

For use as protection and transport eye for work on overhead lines.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Total length (lG)
Diameter
Weight
GTIN
PU

Storage Device


Specifications

Type
Part No.
Dimensions
Diameter
Hole spacing
Diameter (hole)
Colour
Weight
GTIN
PU

For PHE4, with M12 threaded Bushing


Specifications

Type
Part No.
Total length (lG)
Length (handle) (lH)
Diameter
Material
Weight
GTIN
PU

For PHE4 and PHE III, with universal Gear Coupling

Handle end fitting with plastic plug-in coupling as extension handle.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Nominal voltage (UN)
Total length (lG)
Length (handle) (IH)
Diameter
Material
End fitting
Weight
GTIN
PU
  • IS ZK STK 670
  • 766 368
  • 30 kV
  • 670 mm
  • 265 mm
  • 30 mm
  • Glass-fibre reinforced polyester tube
  • Plug-in coupling for extending the handle
  • 340 g
  • 4013364115026
  • 1 pc(s)
  • Specifications (PDF)
  • More

HV STK Extension Handle

Plug-in coupling at both ends for extending the handle.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Total length
Diameter
Material
Colour
Weight
GTIN
PU

Universal Plastic Case for PHE4, PHE III, PHV and PHV I

With aluminium frame and convoluted foam.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Suitable for
Dimensions
Colour
Weight
GTIN
PU
  • KKL 92 28 12
  • 766 994
  • Voltage detector PHE4, PHE III, PHE, phase comparator PHV
  • 920 x 280 x 126 mm
  • black ●
  • 3,31 kg
  • 4013364247062
  • 1 pc(s)
  • Specifications (PDF)
  • More
    • Further Pictures
      Further Information
  • KKL 127 28 12
  • 766 995
  • Voltage detector PHE4, PHE III, PHE, phase comparator PHV
  • 1270 x 280 x 126 mm
  • black ●
  • 4,38 kg
  • 4013364247147
  • 1 pc(s)
  • Specifications (PDF)
  • More
    • Further Pictures
      Further Information

Artificial Leather Bag, empty

With carrier handle and shoulder strap.

Show SpecificationsHide Specifications

Specifications

Type
Part No.
Suitable for
Dimensions
Colour
Weight
GTIN
PU

Artificial Leather Bag for PHE4, PHE, PHV I, PHE/G


Specifications

Type
Part No.
Suitable for
Dimensions
Colour
Weight
GTIN
PU

Artificial Leather Bag, empty


Specifications

Type
Part No.
Suitable for
Colour
Dimensions
Weight
GTIN
PU

Artificial Leather Bag for PHE4 and PHE


Specifications

Type
Part No.
Suitable for
Dimensions
Colour
DB drawing No.
Weight
GTIN
PU